SAF OPAL Ethernet IP Interface MS6 SERIES Instrukcja Użytkownika Strona 12

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 13
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 11
Opal Pro to SAF GlobalData
Page 12
1.06 (Word 9)
Analog Input
Analog input value in Volts X 100
1.07 (Word 10)
Relay Status
Status of the Relay Outputs
Bit 0 Running
Bit 1 By-Pass
Bit 2 Shorted SCR
Bit 3 Reverse
Bit 4 Faulted
1.08 (Word 11)
Analog
Output
Analog Output value in Volts X
100
2.01 (Word 12)
Stack Size
Opal Pro Stack Size in Amps
2.02 (Word 13)
Comm
Module Type
0 None
2 Ethernet
2.03 (Word 14)
Firmware
Version
Opal Pro Firmware Version x 100
10.01 (Word 15)
Start/Stop
Control
4 = 2 Wire
5 = 3 Wire
6 = Comm Module
10.02 (Word 16)
Ramp Time
Time is seconds
10.03 (Word 17)
Step Current
In % of nameplate current
10.04 (Word 18)
Current
Reference
7 = Internal
8 = Analog Input
9 = Comm Module
10.05 (Word 19)
Phase Angle
10 = Internal
11 = Analog Input
12 = Comm Module
10.06 (Word 20)
Jog Accel
Current Limit
In % of nameplate current
10.07 (Word 21)
Jog Current
Limit
In % of nameplate current
10.08 (Word 22)
Jog Ramp
Time is seconds x 10
11.01 (Word 23)
Stop Mode
13 = Coast
14 = Soft Stop
15 = DC Injection
11.02 (Word 24)
Soft Stop
Step
In % of incoming line voltage
11.03 (Word 25)
Soft Stop
Ramp
Time in seconds
11.04 (Word 26)
DCI Current
In % of nameplate current
11.05 (Word 27)
DCI Time
Time in seconds
Przeglądanie stron 11